RESEARCH PAPER
Microbial air contamination in indoor environment of a university library
 
More details
Hide details
1
Department of Microbiology and Biotechnology, Institute of Ecology and Environment Protection, Nicholas Copernicus University, Toruń, Poland
 
 
Ann Agric Environ Med. 2012;19(1):25-29
 
KEYWORDS
ABSTRACT
The present study was aimed at evaluating the number of bacteria and mould fungi in the indoor and outdoor environment of Toruń University Library. The sampling sites were located in the rooms serving the functions typical of libraries (i.e. in the Main Reading Room, Current Periodicals Reading Room, Collections Conservation Laboratory, Old Prints Storeroom, in rooms serving other (non-library) functions (i.e. main hall, cafeteria, and toilet) as well as outside the library building. The analyses reveal that the concentrations of bacterial as well as fungal aerosols estimated with the use of the impaction method ranged between 101-103CFU-m-3, which corresponds to the concentrations normally observed in areas of this kind. Evaluation of the hygienic condition of the studied areas was based on the criteria for microbiological cleanliness in interiors submitted by the European Commission in 1993. According to this classification, the air was considered to be heavily or moderately contaminated with bacteria, while the air contamination with mould fungi was described as low or moderate. The air in the Old Prints Storeroom was considered the least contaminated with microbial aerosol.
REFERENCES (25)
1.
Dacarro C, Picco AM, Grisoli R, Redolfi M. Determination of aerial microbiological contaminations in scholastic sports environment. J Appl Microbiol. 2003; 95: 904-12.
 
2.
Wojtatowicz M, Stempniewicz R, Żarowska B, Rymowicz W, Robak M. Mikrobiologia ogólna. Wydawnictwo Uniwersytetu Przyrodniczego we Wrocławiu, Wrocław 2008.
 
3.
Karwowska E. Microbiological air contamination in farming environment. Pol J Environ Stud. 2005; 14: 445-449.
 
4.
Allsopp D, Seal KJ, Gaylarde ChC. Introduction to biodeterioration (2 nd ed.). Cambridge University Press 2004.
 
5.
Górny RL. Fungal and bacterial propagules as indoor air contaminants: characteristic, release mechanisms, detection. Sosnowiec. Instit Occup Med & Environl Health Publ. 2004.
 
6.
Łebkowska M. Rola mikroorganizmów w niszczeniu materiałów użytkowych. In: Problemy jakości powietrza wewnętrznego w Polsce 2003. Wydawnictwo Instytutu Ogrzewnictwa i Wentylacji Politechniki Warszawskiej, Warsaw 2004, 141-148.
 
7.
Björnsson E, Norback D, Janson C, Widstrom J, Palmgren U, Strom G, Boman G. Asthmatic symptoms and indoor levels of microorganisms and house dust mites. Clin Exp Allergy. 1995; 25: 423-431.
 
8.
Newson R, Strachan D, Corden J, Millington W. Fungal and other spore counts as predictors of admission for asthma in the Trent region. Occup Environ Med. 2000; 57: 786-792.
 
9.
Siersted HC, Gravesen S. Extrinsic allergic alveolitis after exposure to the yeast Endotorula rubra. Allergy. 1993; 48: 298-299.
 
10.
Renn P, Jankun TM, Belanger K, Bracken MB, Leaderer BP. The relation between fungal propagules in indoor air and home characteristics. Allergy. 2001; 56: 419-424.
 
11.
Dales RE, Zwanenburg H, Burnett R, Franklin CA. Respiratory health effects of home dampness and molds among children. Am J Epidemiol. 1991; 123: 196-203.
 
12.
Ross MA, Curtis L, Scheff PA, Hryhorczyk DO, Ramakrishnan V, Wadden RA, Persky VW. Association of asthma symptoms and severity with indoor bioaerosols. Allergy. 2000; 55: 705-711.
 
13.
Lipiec A. Grzyby pleśniowe – ważny antygen środowiskowy. Terapia. 1997; 3: 27-30.
 
14.
Jain AK. Survey of bioaerosol in different indoor working environments in central India. Aerobiologia. 2000; 16: 221-225.
 
15.
Karbowska-Berent J, Górny RL, Strzelczyk AB, Wlazło A. Airborne and dust borne microorganisms in selected Polish libraries and archives. Build Environ. 2011; 46: 1872-1879.
 
16.
Pascual L, Pérez-Luz S, Yáñez MA, Santamaría A, Gilbert K, Salhot M, Apraiz D, Cetalán V. Bioaerosol emission from wastewater treatment plants. Aerobiol. 2003; 19: 261-270.
 
17.
Commission of the European Communities (CEC): Indoor Air Quality and Its impact on Man. Report No. 12. Biological Particles in Indoor Environment, Luxemburg 1993.
 
18.
Górny RL, Dutkiewicz J. Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries. Ann Agric Environ Med. 2002; 9: 17-23.
 
19.
Dutkiewicz J, Górny RL. Biologiczne czynniki szkodliwe dla zdrowia – klasyfikacja i kryteria oceny narażenia. Med Pr. 2002; 53: 29-39.
 
20.
Wlazło A, Górny RL, Złotkowska R, Ławniczek A, Łudzeń-Izbińska B, Harkawy AS, Anczyk E. Narażenie pracowników na wybrane szkodliwe czynniki biologiczne w bibliotekach województwa śląskiego (Workers’ exposure to selected biological agents in libraries of upper Silesia) Med Pr. 2008; 59: 159-170.
 
21.
Górny RL, Wlazło A, Krysińska-Traczyk E, Strzelczyk AB, Lis DO, Łudzeń-Izbińska B, et al. Microbial contamination of water – damaged storerooms of libraries. Proc Indoor Air. 2005; 2: 1464-1468.
 
22.
Karbowska-Berent J, Górny RL, Strzelczyk AB, Wlazło A. Airborne and dust borne microorganisms in selected Polish libraries and archives. Build Environ. 2011; 46: 1872-1878.
 
23.
Cox CS, Waters CM. Bioaerosols handbook. Lewis Publishers, New York 1995.
 
24.
Muszyński A, Czerwińska A, Chruślińska I. Ocena jakości powietrza wewnętrznego pod względem mikrobiologicznym w pomieszczeniach dydaktycznych Wydziału Inżynierii Środowiska Politechniki Warszawskiej. Warsaw 1992.
 
25.
Lugauskas A, Krikštaponis A. Microscopic fungi found in libraries of Vilnius and factors affecting their development. Indoor Built Environ. 2004; 13: 169-182.
 
eISSN:1898-2263
ISSN:1232-1966
Journals System - logo
Scroll to top