HPLC analysis of potentially harmful substances released from dental filing aterials available on the EU market

Konrad Małkiewicz 1, Alfred Owoc 2, Mariusz Kluska 3, Kinga Grzech-Leśniak 4, Jadwiga Turło 5
1 - Department of Orthodontics, Medical University of Warsaw, Poland
2 - College of Public Health, Zielona Góra, Poland
3 - Institute of Chemistry, Siedlce University of Natural Sciences and Humanities, Poland
4 - Private Practice, Krakow, Poland
5 - Department of Drug Technology and Pharmaceutical Biotechnology, Medical University of Warsaw, Poland
Ann Agric Environ Med
2014; 21 (1):
ICID: 1095346
Article type: Original article
 
 
Introduction. Incomplete cross-linking of composite dental materials leads to their susceptibility to degradation in the environment of non-organic and organic solvents, contributing to the release of chemical compounds which are potentially harmful to living organisms.
Objective. The aim of the study was an evaluation in in vitro conditions of releasing of potentially toxic substances from six dental composite materials available in EU countries.
Materials and methods. The following compounds released from the samples stored in water were analyzed: bisphenol A (BPA), triethylene glycol-dimethacrylate (TEGDMA), urethane dimethacrylate (UDMA) and ethylene glycol dimethacrylate (EDGMA). Analysis of the substances was performed with the use of high performance liquid chromatography, after the following incubation periods: 1 hour, 24 hours, 7 days and 30 days.
Results. Among the analyzed substances, after 1 hour of incubation, the highest average concentration was found for TEGDMA – 2045 μg cm-3 (in Herculite XRV material), after 24 hours – for UDMA 4.402 μg cm-3 (in Gradia Direct Anterior material) and after 7 and 30 days for TEGDMA: 8.112 and 6.458 μg•cm-3 respectively (in Charisma material).
Conclusions. The examined composites used for reconstruction of hard tissues of teeth remain chemically unstable after polymerization, and release potentially harmful substances in conditions of the present study. The dynamics of the releasing of potentially harmful substances is correlated with the period of sample storage in water.
PMID 24738503 - click here to show this article in PubMed
  FULL TEXT STATS

Recommend this article to:

Name:
E-mail:
From:
Language:


Related articles in IndexCopernicus™
     High performance liquid chromatography (HPLC) [12 related records]
     bisphenol A (BPA) [2 related records]
     dental composite [5 related records]



 

Related articles

D Raczkiewicz, A Owoc,
Pain involving the motor system and serum vitamin ...
Abstract Introduction and objective. Since the role of vitamin D is essential in numerous biological processes its deficiency was suggested to be a risk factor for e.g. osteoporosis, musculoskeletal pain and spine pain. The purpose of the st...
ABSTRACT
M Owoc,  Piasny,
Adaptacyjne systemy agentowe we współczesnym śr...
Ewolucja priorytetów konsumenckich, ukierunkowana na oszczędność czasu transakcji, spersonalizowane podejście i ogólne odejście od ceny jako jedynego i najważniejszego wyznacznika jakości produktów i usług spowodowały nasilenie dynamiki z...
ABSTRACT
K Małkiewicz, P Wychowański,
Uncompleted polymerization and cytotoxicity of den...
 INTRODUCTION Composite materials used in many areas of modern dentistry are made of organic matrix, inorganic filler, coupling agent/ silane and systems of initiators, catalysts and polymerization inhibitors. Matrix of polymer-based composite...
ABSTRACT