Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey

Nergüze Aydin Çakir 1, Füsun Bahriye Uçar 1, Alev Haliki Uztan 1, Cengiz Çorbaci 1, Onur Akpinar 1
1 - Department of Biology, Basic and Industrial Microbiology Section, Faculty of Science, Ege University, Bornova-Izmir, Turkey
Ann Agric Environ Med
2013; 20 (1):
ICID: 1041683
Article type: Original article
 
 
Introduction and Objectives. Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated.
Materials and Methods. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 – March 2007.
Results. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m3 , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1.
In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals.
Conclusions. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.
PMID 23540222 - click here to show this article in PubMed
  FULL TEXT STATS

Recommend this article to:

Name:
E-mail:
From:
Language:


Related articles in IndexCopernicus™
     Aerococcus sp. [0 related records]
     Staphylococcus sp. [2 related records]
     nosocomial infections [62 related records]
     Enterococcus sp. [1 related records]



 

Related articles

A Bianchi, F Pregliasco,
Genotypic diversity of Legionella pneumophila in e...
Objective. The study aimed to evidence previous cases of legionellosis or proven or suspected pneumonia in seven hospital facilities for the mentally disabled in Northern Italy, where no clinical surveillance had been previously carried out. A...
ABSTRACT
, ,
Antimicrobial Resistance Pattern and Frequency of ...
Background: Strains belonging to Enterobacter genus are important opportunistic nosocomial pathogens. Resistance to broad-spectrum antibiotics often complicates the treatment of Enterobacter infections. Aim and Objectives: The present study was a...
ABSTRACT
B Kayaaslan , A But,
Intensive Care Unit-Acquired Infections and Associ...
Objective: This study aimed to investigate epidemiological haracteristics of infections and risk factors for mortality in intensive care unit (ICU) patients. Methods:A total of 164 patients hospitalized at Ankara Numune Education and Research Hospi...
ABSTRACT